Specifications 1/3 HP Model BW1033 1/2 HP Model BW1050
GPH @ 0’ 3600 4400
GPH @ 10’ 2600 3200
G/Wh 6.2 6.3
Pump diameter 6.2” 6.2”
Volts 115V, 60Hz 115V, 60Hz
Amps 3.5 4.2
Important Safety Instructions
SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS for the Basement Watchdog pumps. You will need to refer to
it before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.
ALWAYS disconnect the pump from the power source before servicing or making
adjustments.
NEVER handle the pump or motor with wet hands or when standing on a wet or damp
surface while the pump is plugged into the power source.
MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is
wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain
that it is only connected to a properly grounded, 3-prong receptacle. If you have a 2-
prong receptacle, have a licensed electrician replace it with a 3-prong receptacle
according to local codes and ordinances.
NEVER bypass grounding wires or remove the ground prong from the plug.
DO NOT use an extension cord. The electrical outlet should be within the length of the
pump’s power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.
DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.
Avoid kinking the cord.
MAKE SURE the supply circuit has a fuse or circuit breaker rated to handle the power
requirements noted on the nameplate of the pump.
DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
DO NOT expose the control unit to rain or snow.
DO NOT operate the pump or control unit if it has been damaged in any way.
DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.
DO NOT disassemble the pump or control unit. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
CAUTION
WARNING
Risk of electric shock. To reduce this risk, observe the
following precautions.
To reduce the risk of hazards that can cause injury or
property damage, observe the following precautions.
Basement Watchdog
Sump Pumps
Instruction Manual &
Safety Warnings
Items Included:
Pump
Dual float and controller
Stainless steel hose clamp
You may also need:
A 1-1/2” PVC pipe adapter to screw
into the discharge hole on top of
the pump
1-1/2” rigid PVC pipe to connect
to the existing plumbing
A check valve or rubber union
PVC pipe cleaner and cement
Wire ties or hose clamps
The Dual Float
& Controller
1/2 HP Pump
BW1050
1/3 HP Pump
BW1033
Models
BW1033
and
BW1050
G/Wh = Gallons per Watt Hour G/Wh = GPH/(Amps x Volts)
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - Safety Warnings

Specifications 1/3 HP Model BW1033 1/2 HP Model BW1050GPH @ 0’ 3600 4400GPH @ 10’ 2600 3200G/Wh 6.2 6.3Pump diameter 6.2” 6.2”Volts 115V, 60Hz 115V, 6

Seite 2 - Product Operation

• The Basement Watchdog BW1033 and BW1050 come equipped with a built-inair relief valve located on the top of the pump. While the pump is active,some

Seite 3 - Troubleshooting

Dual Float Controller This control box contains a piggyback switch that powersthe Basement Watchdog Dual Float. The Dual FloatController will activat

Seite 4 - Limited Warranty

© Glentronics, Inc. 20141806044 02/144Limited WarrantyBy opening this package and using this GLENTRONICS, INC. product, you are agreeing to be bo