Instruction Manual& Safety WarningsIMPORTANT: Even if you have the Basement Watchdog SpecialBackup Sump Pump System installed by someone
Page 9If your battery looks like the battery above,follow these instructions:1. Remove the cover of the battery box bypushing in the tab
into the pump connector on the back of thecontrol unit. Keep the backup pump wire, theAC pump wire, and the float wire separatefrom each other
Page 11Understanding the Warnings & AlarmsThe Basement Watchdog control unit features aseries of warning lights that pinpoint potentialproblems.
REFER TO THE PHOTOS AT LEFT1. Unplug the charger from the wall outlet.2. Remove the cover of the battery box bypushing in the tabs on the
8. (a) If your battery has six (6) caps on the top,rinse and dry the cap with the extra hole fromthe old battery to remove any residue.Replace t
4Pump When the water rises in the sump pit andactivates the float switch, the pump will beginpumping, and the “Pump was activated” light
5PowerThere are several causes for power failure. Themost common is a power outage by your electriccompany. During this emergency, the BasementWatch
Page 16MAINTENANCE CHECK LISTMaintenance should be performed 1-2 times peryear1. Lift the float switch as described at left.2. Remove all debris from
Page 17The battery fluid is low . . . . . . . . . . . . . . . . . . . . . . . . . . .The fluid sensor is installed improperly . . . . . . . . . . . .
Page 18Limited WarrantyGLENTRONICS, INC. warrants to the original retail purchaser that all of its pump, switch, sensor, batterybox and control unit p
Important Safety Warnings & InstructionsSAVE THESE INSTRUCTIONS. This manualcontains important SAFETY WARNINGS andOPERATING INSTRUCTIONS
© 2008, Glentronics, Inc. 1806085 08/13CHECK OUT THESE OTHER BASEMENT WATCHDOG PRODUCTSAC PUMPSIndustrial Grade Pumps for the Residentia
IntroductionThe Basement Watchdog Special backup sumppump system is battery-operated. It is designedas an emergency backup system to support you
Pump & Pipe Installation InstructionsThere are two basic methods that can be used toinstall the pump, a direct discharge to
Page 4Pump & Pipe Installation InstructionsINSTALLATION A:DIRECT DISCHARGE TO THE OUTSIDE OF THEBUILDING (Diagram A)Unplug the main AC pump
Page 5Pump & Pipe Installation InstructionsINSTALLATION B:CONNECTION TO AN EXISTING DISCHARGE PIPE(Diagram B)Depending on your installation re
Page 6Pump & Pipe Installation InstructionsINSTALLATION C:DIRECT DISCHARGE TO THE OUTSIDE OF THEBUILDING FOR NARROW SUMP PITS (Diagram C)Unplug th
Page 7Pump & Pipe Installation InstructionsINSTALLATION D:CONNECTION TO EXISTING DISCHARGE PIPEFOR NARROW SUMP PITS(Diagram D)Depending on you
Page 8Battery InstructionsA new Basement Watchdog 7.5 Hour StandbyBattery will run this system for a minimum of 7.5hours continuously. Howeve
Kommentare zu diesen Handbüchern