Seitenansicht 9
Understanding the
Warnings & Alarms
The Basement Watchdog Special con-
trol unit features a series of warning
lights that pinpoint potential problems.
In addition, an alarm sounds to alert you
to the problem. In some cases, the
lights and alarm will go off automatically
when the problem has been solved. In
others, the RESET button must be
pushed to silence the alarm. Refer to
the table below for a quick review of the
features and their corresponding alarm
status.
SILENCING THE ALARM
DURING AN EMERGENCY
Your Basement Watchdog Special sump
pump system is equipped with a plug that
allows you to silence the POWER and
PUMP alarms during an emergency or
power failure. The plug is located in a
bag attached to the charger cord. To
silence the alarm, insert the plug into the
jack on the right side of the control unit.
The plug must be removed and the alarm
should be reactivated when the emer-
gency is over, or when the power is
restored. This plug does not effect the
BATTERY, FUSE, and WATER alarms.
To reactivate the alarm, remove the plug
and place it back in the bag on the
charger cord. If your pump was activated
during the power outage, the PUMP
alarm will still be sounding. Press the
RESET button to silence that alarm.
If you do not remove the plug, you will
not be warned the next time a POWER
or PUMP emergency arises.
BATTERY ALARM
This light and alarm will go on when the
control unit senses that the battery has
approximately
1
/
2
hour of pumping
energy left. This could occur when the
pump has been running for many hours
and is reaching the last half-hour of
operating power, or it could occur
because the battery is getting old and
should be replaced.
The alarm can also be triggered by
corrosion of the battery cable and the
battery terminals. Clean and tighten the
battery terminals as described at the
right. If this warning goes on while the
pump is running, you will have a minimum
of
1
/2 hour to replace the battery. (In most
cases, the pump does not run contin-
uously, and therefore, you actually have
much longer.) In a severe emergency, if a
replacement battery is not available, you
could temporarily use your car battery.
Once the AC power is restored, the
battery will recharge, unless it is old or
damaged. The alarm will go off when the
AC power is restored and the pumping
energy reaches
1
/2 hour or more.
In the event that your Basement
Watchdog Special sump pump system
has been called on to pump for
extended periods of time, the battery
can become very depleted. In this
condition, when the AC power is
returned to the unit, a BATTERY alarm
will continue to sound. The battery may
need a longer period to recharge.
For a fast recharge, an automotive or
marine battery charger can be used to
recharge the battery.
When another
charger is used, first disconnect the
controller from the battery.
To silence the alarm while the battery is
recharging, do the following:
1. Insert the plug into the jack on the
right side of the control unit.
2. Press the TEST button, but not the
RESET button.
3. Leave the system in this condition
for 24 hours.
4. After a 24-hour charging period,
remove the plug and press the
RESET button.
5. If the battery is recharged, all
alarms will be off.
6.
If the alarm is still sounding, the
battery is defective or the posts are
corroded. Clean the terminals. If the
alarm still sounds, replace the battery.
TO CHECK FOR CABLE OR
TERMINAL PROBLEMS
IMPORTANT: REVIEW THE
SAFETY INSTRUCTIONS
BEFORE YOU PROCEED
1. Unplug the charger from the wall
outlet.
2. Remove the battery cables and
clean the battery posts with a bat-
tery post terminal cleaner or a wire
brush and a 50/50 solution of water
and baking soda. Do not allow the
soda water to enter the battery.
Thoroughly dry the posts and apply a
thin coat of petroleum jelly or another
terminal protective material.
3. Clean the corrosion off of the con-
nectors on the end of the battery
wires. Use a stiff brush or sand-
paper.
4. Replace the battery cables, RED to
the POSITIVE (+) post, and BLACK
to the NEGATIVE (-) post.
5. Plug the charger into the wall outlet.
6. You may have to press the RESET
button to silence the pumping alarm.
Page 9
Warning
BATTERY
FUSE
WATER
PUMP
POWER
Alarm shuts off
automatically
when problem
is corrected
Yes
Yes
Yes
No, must push
"RESET" button
Yes
FRONT PANEL OF CONTROL UNIT
What to do
Terminals corroded or battery defective
Clean terminals or replace battery
Replace with 25 amp auto fuse
If fuse blows again, replace pump
Add distilled water to battery
Pump was activated
Check main pump for failure
Check circuit breaker & charging plug
If power is on, replace charger
Charger Operating
Warning
BATTERY
FUSE
WATER
PUMP
POWER
Push to
Test
System
Push to
Silence
Pump Alarm
Battery Operated
SUMP PUMP
TEST
RESET